Bridge Part 1

Shows how to start a three-unit bridge in Copy mode, the best way to design any case of more than two units when there is a wax-up or a pre-op. The missing tooth and the abutments are labeled on the tooth chart, and the models are checked in Align Models: here the preparation scan was not related to the other two, so it is matched with Auto Align while the other models are hidden. Then the pontic outline and the two abutment margins are drawn, each margin is checked against its tooth number, a common place for mistakes, and the path of draw for the whole bridge and the connector thickness are reviewed before Design.

A bridge is charted in the prescription: abutment, pontic, abutment, all connected. Each abutment needs its margin on the prepared scan; the pontic gets a tissue outline instead of a margin. A three-unit bridge opens the Bridge panel at Design. Other layouts with pontics are copied from the pre-op or wax-up, each pontic seated on its tissue outline.

  • Path of drawOne common path of draw for both abutments: from Axis / Spacer when confirmed, otherwise proposed to leave no undercut on either. View along path looks down it; Adjust opens Axis / Spacer.
  • Draw in MarginsThe pontic's tissue outline: proposed until you draw it in Margins yourself (then Edit in Margins).
  • ConnectorsWidth and Height (default 3 × 3 mm), Center above margins (3 mm), Side offset (0 mm) and Lift off tissue (0 mm). Review connector dimensions for your intended material.
  • Build bridge previewBuilds both abutment crowns on the common path, then the pontic and the connectors, into one closed bridge. Cancel stops it; scans and margins stay unchanged. Changing only a connector reuses the crowns.

The bridge is a preview: fit, thickness, tissue fit and milling are not validated yet, and a preview cannot be sent to milling.