A copy is the patient's own tooth. Design takes the tooth from the pre-op or wax-up scan (assigned as Non-Working on the working jaw), cuts away the preparation down to the margin and leaves the cement spacer inside, along the confirmed path of draw (or the preparation's own direction). Above the height of contour it stays identical to the pre-op, and it keeps the pre-op's own bite: a copy is never trimmed against the opposing teeth.

  • Close contactsThe switch in Combine / Boolean (Carve restoration), on by default and kept in this browser. On: copied crowns touch their neighbours at 20 µm and are trimmed out of them. Off: the pre-op's own contacts are kept, open ones included.

With a pre-op and three or more units the copy starts at once, without the Copy / AI card. A copy needs every tooth of the Rx to have its margin; each pontic is seated on its tissue outline drawn in Margins.