A common Model Match error: after margins are drawn for an onlay preparation on a second molar and the path of draw is set, Design reports that the margin is on the opposing scan and must be reassigned to the prepared scan. The dentist shows the fix: go to Model, Edit Models, Match Models, see that the model holding the margin was labeled wrongly, set it to Maxilla Working, confirm and continue with the design. He notes this naming slip happens often when rushing.

Opens Model Match, where each scan gets its role: upper or lower jaw, prepared or pre-op, bite. Design and the contacts follow these roles, so check them whenever a case is new or a scan is replaced.